SINGLE CORE PVC INSULATED,

ANNEALED COPPER,

CONDUCTOR (450/750V)

solid conductor
stranded conductor
  1. Rated Voltage (kV): (0.45/0.75).
  2. Cables sizes (Cu) (mm2): 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240,300,400,500,630.
  3. Cable Construction: Cu, Single Core with PVC Insulation.
  4. Applicable International Standard Specification: IEC, BS, SASO.

SINGLE CORE XLPE INSULATED,

ANNEALED COPPER

CONDUCTOR (600V)

  1. Rated Voltage (kV): (0.45/0.75).
  2. Cables sizes (Cu) (mm2): 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400, 500, 630.
  3. Cable Construction: Cu, Single Core with XLPE-LSHF Insulation.
  4. Mica Tape over conductor for fire resistance cable application available on customer request.
  5. Applicable International Standard Specification:
    IEC 60502-1

Rated Voltage (kV): (0.6)

Cables sizes (AWG): 8, 10, 12, 14 & 16.

Cable Construction: Cu, High Heat Resistant PVC insulation, with Nylon Jacket.

  • A 19-wire combination round-wire Unilay stranded conductor.
  • PVC insulation with maximum 90 °C Dry and 75 °C in wet.
  • Nylon jacket shall be extruded tightly over the insulation

Applicable International Standard Specification: Accordance with the latest edition of UL-83.

Rated Voltage (kV): (0.3/0.5 & 1KV)

Cables sizes (mm2): 1.5 up to 300mm2.

Cable Construction: Cu, PVC, PVC 300/500 & 1 KV as required.

  • Flexible plain annealed copper conductors. All conductors are in accordance with IEC 60228 Class-5.
  • PVC rated 90 °C at normal operation.
  • An extruded layer of colored PVC compound, which is compatible with the maximum operating temperature of the conductor.

Applicable International Standard Specification: accordance with the latest edition of BS EN 50525-2-11:2011 (BS 6500).

MULTI CORE CABLES, PVC INSULATED & PVC SHEATED, (300/500V)
  1. Rated Voltage (kV): (0.3/0.5).
  2. Cables sizes (Cu) (mm2): 1.0, 1.5, 2.5, 4, 6, 10, 16, 25, and 35.
  3. Cable Construction: Cu, Multi core with PVC Insulation and PVC outer sheath.
  4. Applicable International Standard Specification: IEC, BS.
FLAT TWIN & FLAT THREE CORE CABLES, PVC INSULATED & PVC SHEATED, (300/500V)
  1. Rated Voltage (kV): (0.3/0.5).
  2. Cables sizes (Cu) (mm2): 1.5, 2.5, 4,6, 10, 16.
  3. Cable Construction: Cu, Flat Twin or Tripple with PVC Insulation and PVC outer sheath.
  4. Earth continuity conductor available on customer request.
  5. Applicable International Standard Specification: IEC, BS, SAS